Eppendorf 5702 r pdf function

Eppendorf 5702r refrigerated centrifuge marshall scientific. Centrifuge 5425 centrifuges, centrifugation eppendorf. Please perform a manual swingout test before starting the centrifuge run to make sure the. Soft brake function for slow acceleration and braking. Optimizes air flow minimizes sample warming during run 5702 fasttemp function for fast precooling 5702 rrh active heating guarantees high temperature accuracy during the entire centrifugation cycle only 5702 rh eco shutoff engages after 8 hours of nonuse to reduce energy consumption and extend compressor life 5702 rrh. Centrifuge 5418 r centrifuges, centrifugation eppendorf. The 5702 family of low speed, general purpose centrifuges was especially designed to meet. Equipment centrifuges eppendorf centrifuges and rotors swingbucket rotor a4 38, for centrifuge 5702, 5702r and 5702rh. Eppendorf 5702 centrifuge package package provides centrifuge plus rotor and adapters. Centrifuge 5424 r is the refrigerated 24place standard microcentrifuge for temperature.

Now, the rotor program has been expanded with additional eppendorf quicklock rotors. Eppendorf centrifuge model 5702 5702r 5702rh eppendorf. Press and hold down open and shor t button simultaneously for at least 5. To this day, the eppendorf name remains synonymous with creative design, innovative technology and reliable performance that stand the test of time. At set rpm function starts the timer when the selected rotational speed is reached.

Centrifuge 5702 centrifuge 5702 r centrifuge 5702 rh nist. It allows for molecular applications in tubes up to 250 ml and offers additional swingbucket and fixedangle rotors as well as deepwell plate capacity for increased versatility. Centrifuge 5418 r 360view centrifuge5418r request a demo 18place capacity centrifuges for molecular biology that are specifically designed for low to medium capacity in 1. Eppendorf 5702 series centrifuge model 5702rh package. Centrifuge 5425 centrifuges, centrifugation eppendorf nordic. Also observe the instructions for use of the accessories. Eppendorf centrifuge s 5702, 5702r, and 5702 rh performance. Refrigerated centrifuge model 5702r eppendorf mg scientific. Eppendorf centrifuge model 5702 5702r5702rh can be used in a wide range of settings, from the clinical lab to the cell culture lab. Centrifuges 5702 5702 r 5702 rh description the 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low to midthroughput clinical research and cell culture labs. Equipment centrifuges eppendorf centrifuges and rotors swingbucket rotor a438, for centrifuge 5702, 5702r and 5702rh. Compare eppendorf 5702 r centrifuges from eppendorf on.

Tips and tricks helpful infographics to support your daily work. The centrifuge 5702 5702 r 5702 rh is intended exclusively for indoor use and for separating aqueous solutions and suspensions of various densities in approved test tubes. Centrifuge 5427 r was designed with highthroughput research applications in mind. If space is a limited resource in your lab, eppendorfs rolling cabinet can give you the freedom and flexibility to use your centrifuge 58045804 r or 58105810 r wherever you need it. Eppendorf 5702 centrifuge package w4 x 100ml swing bucket. Choose the centrifuge 5427 r if a 24place microcentrifuge e. The versatility is reflected in the available rotor. Centrifuge 58045804 r is a high speed centrifuge for medium capacity needs. Inform yourself about safe operation of centrifuges. Optimized for cell separation by gradient centrifugation. Front of the centrifuge 5702 rh is structurally identical to that of the 5702 r. With this sound fundamental experience eppendorf is proud to serve you as your expert partner in centrifugation. Centrifuge 5920 r delivers extraordinary high capacity in a very compact and ergonomic product design.

Swingbucket rotor a438, for centrifuge 5702, 5702r and 5702rh. Centrifuge 57025702 r5702 rh english en 2 safety 2. Its varying rectangular buckets, round buckets and adapters make it specially well suited to centrifugation of blood sampling systems, falcons. Eppendorf 022626256 5702 r variablespeed multipurpose. Fasttemp function for fast precooling 5702 r rh active heating guarantees high temperature accuracy during the entire centrifugation cycle only 5702 rh eco shutoff engages after 8 hours of nonuse to reduce energy consumption and extend compressor life 5702 r rh. Centrifuge eppendorf 5702r refrigerated high performance centrifuge very compact design the eppendorf 5702r is a valuable aid even in the small laboratory, where noise can be an issue and ensures whisperquiet operation even at maximum speed. Centrifuge 5702 centrifuge 5702 r centrifuge 5702 rh. Fasttemp function for quick precooling and maximized temperature accuracy inside the rotor. You will see this symbol on your centrifuge and at a number of points throughout this manual. First set the required program data with the time and speed dial adjustors. It offers efficient cooling performance for up to 24 x 1. The eppendorf 5702r refrigerated centrifuge is a lowspeed, general purpose centrifuge designed to meet low to midthroughput clinical research and cell culture lab needs.

Read this operating manual completely before using the device for the first time. T o secure the centrifuge paramet ers against unint entional adjustment, the centrifuge 5702 and the centrifuge 5702 r 5702 rh allows y ou to lock in the par ameters y ou need. Centrifuge 5427 r centrifuges, centrifugation eppendorf. Centrifuge 5702 5702 r 5702 rh english en 1 operating instructions 1. The 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low to midthroughput clinical research and cell. Meet the requirement of low to midthroughput clinical research and cell culture labs with these low speed, general purpose centrifuges. With various fixedangle and swingbucket rotors available, they can accommodate almost any kind of tubes. Fasttemp function for fast precooling 5702 rrh active heating guarantees high temperature accuracy during the entire centrifugation cycle only 5702 rh eco shutoff engages after 8 hours of nonuse to reduce energy consumption and extend compressor life 5702 rrh. Fasttemp function for fast precooling, temperature settings from 9 c to 4 c 2 program keys to store routine procedures. Eppendorf centrifuge 5702 r community, manuals and.

They are compact in design so that one can fit comfortably on every lab bench, quiet in operation to benefit your work environment. C fasttemp pro function for fast precooling continuous cooling maintains a constant temperature after the run has been completed your samples stay cool. They are compact in design to fit on almost every lab bench, quiet in operation to improve your work environment. A fast temperature function can rapid cool the centrifuge chamber, and a standby cooling mode maintains selected temperatures with the lid closed when the centrifuge is not in use.

The refrigerated centrifuge 5418 r with its 18place capacity rotor is specifically designed for low to medium capacity in 1. Due to its design and the environmental conditions inside the device, the centrifuge 57025702 r5702 rh is not suitable for use in a potentially explosive atmosphere. Centrifuge 5920 r centrifuges, centrifugation eppendorf. The device may only be used in a safe environment, such as in the open environment of a ventilated laboratory or a fume hood. Eppendorf 5702 series centrifuge model 5702 package. Special features for centrifuge 5702 r and centrifuge 5702 rh temperature settings from 9 c to 40 c 5702 r 42 c 5702 rh low access height fasttemp function for fast precooling continuous cooling maintains a constant temperature after the run has been completed your samples stay cool. Clinical packages and cell culture packages include centrifuge, rotor, buckets, and adapters for vacutainer tubes. The 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low to midthroughput clinical research and cell culture labs. This device may only be operated by trained specialist staff. Please also note the operating instructions for the accessories, if applicable.

We introduced our very first centrifuge in 1964 as an integral part of the eppendorf microliter system, and revolutionized life science research practices worldwide. Eppendorf 5702 series centrifuge w4 x 100ml swing bucket. In a compact size, centrifuge 5430 and 5430 r also accommodate rotors for microplates and 1550 ml conical tubes. Centrifuge 5702 r, rotary knobs, refrigerated, without rotor, 230 v50 60 hz catalog no. Aerosoltight eppendorf quicklock lids for simple and safe handling. The eppendorf 5702 family of centrifuges very compact design. With its aerosoltight 48place rotor it handles even the toughest challenges in a safe and reliable manner to provide you the efficiency boost you need. Eppendorf training become an expert with our training program.

Take advantage of the 38 x 58 cm footprint of compact design, which can be integrated into any workplace. They must have carefully read the operating manual and be familiar with the function of the device. The present design and ambient conditions inside eppendorf centrifuges mean that they are not suitable for use in a. The speed variable on the eppendorf 5702 r centrifuge can be set in increments of 100 from 100 to 4,400 rpm. These centrifuges spin rotors for eppendorf tubes and pcr strips as you would expect from any microcentrifuge. With its compact design, quiet operation, and six different rotor options, the 5702r is ideal for many labs. Jun 25, 2019 eppendorf centrifuge model rrh can be used in a wide range of settings, from the clinical lab to the cell culture lab. Centrifuge 58045804 r5810 5810 r operating manual 12 only 5804 r and 5810 r.

The device may only be used in a safe environment, such as in the open environment of a ventilated laboratory or. A fast temperature function can rapid cool the centrifuge chamber, and a standby cooling mode maintains selected temperatures with. With various fixedangle and swingbucket rotors available, they can accommodate almost any kind of tube. Eppendorf centrifuge 57025702r5702rh 5702rh, refrigerated. Eppendorf centrifuge model 57025702r5702rh can be used in a wide range of settings, from the clinical lab to the cell culture lab. Due to its design and the environmental conditions inside the device, the centrifuge 5702 5702 r 5702 rh is not suitable for use in a potentially explosive atmosphere. Standby cooling keeps the 5702 r at set temperature when lid is closed. Use the rolling cabinet if there is not enough space on the regular lab bench or to transport and use the centrifuge in other labs. Eppendorf centrifuge model rrh can be used in a wide range of settings, from the clinical lab to the cell culture lab. Eppendorf 5702 series centrifuge fisher scientific. Nonclinical packaged models 5702, 5702r, and 5702rh use the same rotors, which must be ordered separately see rotors and accessories for. Setting the beginning of time counting at set rpm function.

Eco shutoff engages after 8 hours of nonuse to reduce energy consumption and extend compressor life. Centrifuge 5424 r is the refrigerated 24place standard microcentrifuge for temperature sensitive samples. It has similar dimensions as competing refrigerated 3 liter models and yet features a superior capacity of up to 4. All aerosoltight rotors are equipped with the eppendorf quicklock lids for easy rotor. The refrigerated centrifuge 5427 r was designed with highthroughput research applications in mind. Special features for centrifuge 5702 r and centrifuge 5702 rh temperature settings from 9 c to 40 c 5702 r 42 c 5702 rh fasttemp function for fast precooling continuous cooling maintains a constant temperature after the run has been completed your samples stay cool eco shutoff engages after 8 hours of nonuse to reduce. Description choose either the 5702 model a base, nonheated centrifuge for standard applications, the 5702 r that is a refrigerated model for heatsensitive samples, or the heated and refrigerated 5702 rh model for centrifugation under biological conditions to improve cell viability for more accurate results in downstream application like cell cultivation.